IL-21 is a pleiotropic cytokine that plays a key role in modulating inflammatory responses, including the promotion of autoimmune diseases. Several groups have quantitated circulating levels of IL-21 in plasma and serum samples using various commercial ELISAs. We determined, however, that the most commonly used commercial assays in published literature were not specific or sensitive enough to detect levels of IL-21 in heparin plasma or serum from healthy human individuals. This finding prompted an effort to develop more specific and sensitive methods to quantitate IL-21 in complex biological matrices using proprietary anti-IL-21 antibodies with the Quanterix SiMoA platform and the Meso Scale Discovery (MSD) S-PLEX® format. Assays developed on both technology platforms were characterized in heparin plasma and serum using spike recoveries across a range of concentrations. Each method was able to detect sub-pg/mL levels of IL-21 (predicted Limit of Detection [LOD] of approximately 1.0 fg/mL for both the Quanterix SiMoA and MSD S-PLEX® platforms) which is 200-500 times lower than current commercial assays. Additionally we demonstrated that rheumatoid factor did not interfere with measuring IL-21 in the Quanterix SiMoA assay. Results obtained with the two new ultrasensitive assays showed a strong correlation (r = 0.9428; p < .0001). Additionally, IL-21 levels were significantly increased in samples from patients with Systemic Lupus Erythematosus (mean+/- SD: n = 14, 202.64 +/- 111.47 fg/mL, p = .0001 for Quanterix SiMoA and 275.4 +/- 174.66 fg/mL p = .0001 for MSD S-PLEX®) as well as in samples from patients with Sjögren's Syndrome (mean+/- SD: n = 11, 122.18 +/- 84.50 fg/mL, p = .0029 for Quanterix SiMoA and 183.64 +/- 153.00 fg/mL, p = .0082 for MSD S-PLEX®) when compared to healthy donors (mean+/- SD: n = 11, 38.1 +/- 27.8 fg/mL for Quanterix SiMoA and 58.1 +/- 30.7 fg/mL for MSD S-PLEX®). These ultrasensitive assays, for the first time, allow for the accurate quantitation of human IL-21 in heparin plasma and serum. In addition, these experiments also provide a direct comparison of the MSD S-PLEX® format and Quanterix SiMoA platform technologies, which may have broader implications to future application of these methods to evaluate low abundance proteins in complex biological matrices.
Keywords:IL-21; Interleukin-21; S-PLEX®; SiMoA; Ultrasensitive.
Measurement of IL-21 in human serum and plasma using ultrasensitive MSD S-PLEX® and Quanterix SiMoA methodologies
详见LabEx网站(
www.u-labex.com)或来电咨询!
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
联系电话:4001619919
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家

本网站销售的所有产品及服务均不得用于人类或动物之临床诊断或治疗,仅可用于工业或者科研等非医疗目的。