Introduction: In the past years several new urinary nephrotoxicity biomarkers have been qualified for use in preclinical studies by the FDA and EMA. Subsequently, kits have been developed to measure these urinary biomarkers on multiplex platforms such as the electro-chemiluminescent based immunoassay from MesoScale Discovery (MSD) and the bead-based immunoassay using Luminex xMAP technology (LMX). The aim of the present study was to compare the two multiplex platforms with respect to the capability of their qualified urinary biomarker panels to measure an increase of these biomarkers relative to histopathological changes in an animal model of nephrotoxicity.
Methods: For comparison of the two platforms we used urine samples from a study with the well-characterized nephrotoxin cisplatin (Cp) in male Wistar rats. The following five biomarkers were measured on both platforms: glutathione S-transferase α (αGST), clusterin (CLU), kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL, a.k.a. lipocalin-2) and osteopontin (OPN). The measurements were compared with respect to both the fold increase observed for each biomarker and the absolute concentrations measured in relation to traditional endpoints for nephrotoxicity in clinical pathology and histopathology.
Results: The platform comparison revealed the expected increases of urinary biomarkers after Cp treatment with similar results at the fold change level enabling consistent detection of kidney injury. The comparison of the absolute concentrations of biomarkers measured in the two platforms showed differences, the extent of which was analyte-dependent.
Discussion: By comparison of two widely used multiplex platforms, MSD and LMX, for the detection of renal toxicity biomarkers in urine, we observed the expected increases of these biomarkers in response to Cp administration. Depending on the marker, significant differences could be found when comparing the absolute concentrations thus suggesting that baseline levels for each platform will have to be set separately.
Comparison of the MesoScale Discovery and Luminex multiplex platforms for measurement of urinary biomarkers in a cisplatin rat kidney injury model
详见LabEx网站(
www.u-labex.com)或来电咨询!
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
联系电话:4001619919
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家

上一篇
Gene expression analysis and urinary biomarker assays reveal activation of tubulointerstitial injury pathways in a rodent model of chronic proteinuria (Doxorubicin nephropathy)
下一篇
Evaluation of the relative performance of 12 urinary biomarkers for renal safety across 22 rat sensitivity and specificity studies
本网站销售的所有产品及服务均不得用于人类或动物之临床诊断或治疗,仅可用于工业或者科研等非医疗目的。