Background: Two electrochemiluminescence (ECL) assays were developed which, together, can simultaneously measure serum antibodies against pneumococcal capsular polysaccharides (PnPS) for 17 serotypes. The assays were validated for the 13 PnPS included in the 13-valent pneumococcal conjugate vaccine (PCV13). As recommended by the World Health Organization (WHO), we compared the ECL assays with the WHO reference enzyme-linked immunosorbent assay (ELISA) and derived a threshold corresponding to the 0.35 µg/mL threshold established for the WHO reference ELISA for the non-inferiority comparison and licensure of new PCVs against invasive pneumococcal disease.
Methods: A panel of 452 serum samples from children vaccinated with one of the three licensed PCVs was assessed with the ECL assays and the WHO reference ELISA. The ECL assay threshold for the aggregated seven PnPS included in the 7-valent PCV (PCV7) and serotype-specific thresholds were determined using a receiver operating characteristics (ROC) curve-based approach and Deming regression. To evaluate concordance between the ECL assays and the WHO reference ELISA, serostatus agreement rates between both assays and geometric means of the ratios (GMRs) of concentrations obtained with both assays were calculated.
Results: The thresholds for the seven aggregated PCV7 serotypes obtained with the ROC curve-based approach and Deming regression approximated 0.35 µg/mL (0.38 and 0.34 µg/mL, respectively). Individual thresholds for the PCV13 serotypes ranged between 0.24 and 0.51 µg/mL across both approaches. Serostatus agreement rates using a 0.35 µg/mL threshold for both assays were ≥86.9% for all PCV13 serotypes. GMRs ranged between 0.85 and 1.25 for 11/13 serotypes and were <1.29 for the two remaining serotypes.
Conclusion: The ECL assays were comparable to the WHO reference ELISA and offer a sensitive, time- and serum volume-saving method to quantify serotype-specific anti-PnPS antibodies in pediatric sera. A 0.35 µg/mL threshold will be used for each PCV13 serotype to assess PCV immunogenicity in clinical trials.
Comparison between a new multiplex electrochemiluminescence assay and the WHO reference enzyme-linked immunosorbent assay to measure serum antibodies against pneumococcal serotype-specific polysaccharides
详见LabEx网站(
www.u-labex.com)或来电咨询!
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
基因水平:PCR Array、RT-PCR、PCR、单细胞测序
蛋白水平:MSD、Luminex、CBA、Elispot、Antibody Array、ELISA、Sengenics
细胞水平:细胞染色、细胞分选、细胞培养、细胞功能
组织水平:空间多组学、多重荧光免疫组化、免疫组化、免疫荧光
数据分析:流式数据分析、组化数据分析、多因子数据分析
联系电话:4001619919
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家
联系邮箱:labex-mkt@u-labex.com
公众平台:蛋白检测服务专家

本网站销售的所有产品及服务均不得用于人类或动物之临床诊断或治疗,仅可用于工业或者科研等非医疗目的。